Precision Hot Air Station
Ref. TE-C
本说明书由汉迪丰科技-黄新银整理
JBC会不定时对产品进行升级改动,因此型号也会有所变动,最新型号请联系发布人sales6@handif.com
TE是一款精密高效能热风机,用於快速安全地焊接/拆焊各类型中小型SMD电子元件。
TE有两种工作模式 - 手动作业和参数设置自动控制,这能有效地管理温度和热风流量。它是可以经由功能表自行设置更多的功能参数。
TE精密高效热风工作站配有TE加热器及所有
必要配件,如三脚架丶回流风罩及自动提取器,
这些配件可以使您的工作更加方便。
它也包含自动提取器放置台和一个快速更换热风头的加热柄焊具座。
此版本现提供 USB接口 (B型接口), 未来可连接电脑进行软体升级及提供即时温度/功率曲线。
技术资料
重量 5.4 kg (11.9 lb)
尺寸 See individual modules
电压 230V / 120V / 100V
保险丝 4A (230V), 8A (120V and 100V)
输出功率 300W
温度选择范围 Tamb-450 ºC / Tamb-850 ºF
工作环境温度 10-40 ºC / 50-104 ºF
温度波动范围 +/-20 ºC / +/-36 ºF
防静电
热风风量 4-11 SLPM
包装重量 6.5 kg (14.2 lb)
包装尺寸 475x370x200 mm
Packing List
The following items should be included:
Precision Heater
JTE Control Unit ............1 unit Ref. JTE-1C
JTE-2C JTE-9C
Stand ..................................1 unit Ref. TE-SA
hose set ............................1 unit Ref. TE-TB
Extractor desk* ..............................................1 unit Ref. 0008752
Accessory set
Ref. 0012332
Extractors*
Ref. E2184
E2064 E2052
Protectors*
Ref. P2220
P2230 P2235 P4000 P4010
Tripod*
Ref. T2050
T2250
Suction Tube*
Ref. 0932330
Power Cord .....1 unit Ref. 0009417
(100V/120V) 0009401 (230V)
Manual .............1 unit
Ref. 0015898
Suction Cups*
Ref. 0930110
Ø 10 - 0934050 (x3)
Ø 4.7 - 0934070 (x1)
Nozzles
Ref. TN9209 Ø 3mm TN9208 Ø 4mm TN9080 Ø 5mm
* Not supplied with TE-QC
Features
Adjustable Stand Nozzle Changer
USB-B connector Update the station software from
the JBC website
Activates the suction pump
Suction Tube
Ref. 0932330
For tripods and extractors
Other connectable tool:
Heater hose set
Ref: JT-TA
Precision Heater Hose set
Ref. TE-TB
Heating element
Hot Air switch (On / Off)
The TE-TB works with TE nozzles. Find the model that best suits your soldering needs in www.jbctools.com
Straight Bent
Ø mm Ø mm
Ref. Shape Size
Equipotential connection
To Pedal
Ref. P-005
Press the pedal to start hot air or release to stop.
Power Socket Fuse
TN9209 Straight Ø 3mm TN9208 Straight Ø 4mm TN9080 Straight Ø 5mm TN9787 Bent Ø 3mm
TN9785 Bent Ø 4mm
TN9782 Bent Ø 5mm
Protectors & Extractors
Operation
For small components (fig. 1 and 2). For large components (fig. 3 and 4). We recommend using the protector + tripod We recommend using the extractors
3.
Releasing
Protectors
* Ref. AxB (mm) * Ref. AxB (mm)
Extractors
* Ref. AxB (mm) * Ref. AxB (mm)
Position the extractor with the appropriate suction cup and press the suction button.
Heat the component by pressing the heater button.
The component lifts off automatically when the solder melts.
Current temperature Selected temperature
Time to stop 45 seconds
Temp ºC Air
400 85
400ºC Select
Power 70%
Current air flow
% Instant power supplied to heater
Access Menu (pess key 2 seconds) & Confirm Selection
* Reference Desk
Manual extractor
Program Mode
Menu Screen
Original PIN: 0105
Graph of selected
program
Selected program
Current temperature
Selected air flow Remaining time
Main menu
1 Reset settings
2 Station Settings
3 Program Settings
4 Counters
5 Program version
Exit
Decrease program number
Increase program number
Settings
1 | Temp unit | Celsius | 1 | Programs | |
2 | Maximum temp | 4500C | 2 | Edit program | |
3 | Minimum temp | T OFF* | 3 | Copy program | |
Edit Program This option allows you to edit or create a program. | 4 | Fix temp | 4000C | 4 | Delete program |
First, you must select the program to edit and then modify the points that make up the program. | 5 | Temp Adjust | 00C | ||
Each program is composed of 9 points, each point consisting of 3 parameters:
1. Time (seconds)
2. Temperature (°C / °F)
3. Flow rate (%)
You can delete the last point of the program by selecting “-----” in the time parameter.
Remember that the regulation range permitted by the station is between 150°C and 450°C, so it is not possible to create temperature ramps between room temperature ( T OFF ) and 150°C.
The station can store up to 25 temperature programs. The first three programs are installed as an example.
Copy Program
This option allows you to copy a program.
You must select the program source and its destination (where it will be copied).
Delete Program
This option will allow you to delete a previously selected program.
6
Max air 100%
7 Min air 10%
8 Fix air 40%
9 Time to stop 120 sec 10 Beep ON
11 Pop up ON
12 Change PIN
* Selecting Minimum Temp as “T OFF”, the air blows at room temperature.
Replacing the Heating Element
Pick & Place (not supplied with TE)
Only perform this operation when the element is cold and the unit is disconnected from the mains.
This tool helps you easily place and remove SMDs of any size thanks to the suction pump.
1. Loosen the screw.
2. Pull the heating element away from the handle.
3. Connect the new heating element, ensuring it is pushed all the way in.
4. Tighten the screw.
Heating Element
Ref. 0012374 (100V - 230V - 120V)
Pick & Place
Bent Needles Set
Ref. 0861660
Straight Needles Set
Ref. 0901546
Handle
Ref. 0012697
Precision Heater Hose Set
Ref. TE-TB
Operation
Choose the needle and the suction cup that best fits the component and start working as follows:
1. Ensure that the tool is turned off.
2. Use a spanner to unscrew the connecting nut.
3. When attaching the new tube make sure the rib lines up with the groove on the control unit.
4. Tighten with the spanner.
Insert the needle with the appropriate cup for a correct suction process.
You should avoid the needle
protruding from the lower part.
Once the suction is activated, cover the pen hole with your finger and lift off the component.
Lift your finger to release the
component in the appropriate place.
Before carrying out maintenance or storage, always allow the equipment to cool.
- Clean the station screen with a glass cleaner or a damp cloth.
- Use a damp cloth to clean the casing and the tool. Alcohol can only be used to clean the metal parts.
- Maintain heating element clean prior to storage in order to avoid its oxidation. Rusty and dirty surfaces reduce heat transfer.
- Periodically check all cables and tubes.
- Replace a blown fuse as follows:
-
Do not use the units for any purpose other than soldering or rework. Incorrect use may cause fire.
- The power cord must be plugged into approved bases. Be sure that it is properly grounded before use. When unplugging it, hold the plug, not the wire.
- Do not work on electrically live parts.
- The tool should be placed in the stand when not in use in order to activate the sleep mode.
The soldering tip, the metal part of the tool and the stand may still be hot even when the station is turned off. Handle with care, including when adjusting the stand position.
- Do not leave the appliance unattended when it is on.
- Do not cover the ventilation grills. Heat can cause inflamable products to ignite.
- Use a “non residue” classified flux and avoid contact with skin or eyes to prevent irritation.
- Be careful with the fumes produced when soldering.
- Keep your workplace clean and tidy. Wear appropriate protective glasses and gloves when working to avoid personal harm.
1.
2. Press the new fuse into the fuse holder and replace it in the station.
-
Utmost care must be taken with liquid tin waste which can cause burns.
- This appliance can be used by children over the age of eight and also persons with reduced physical, sensory or mental capabilities or lack of experience provided that they have been given adequate supervision or instruction concerning use of the appliance and understand the hazards involved. Children must not play with the appliance.
- Replace any defective or damaged pieces. Use original JBC spare parts only.
- Repairs should only be performed by a JBC authorized technical service.
- Maintenance must not be carried out by children unless supervised.
Warranty
JBC’s 2 year warranty covers this equipment against all manufacturing defects, including the replacement of defective parts and labour.
Warranty does not cover product wear due to use or mis-use.
In order for the warranty to be valid, equipment must be returned, postage paid, to the dealer where it was purchased.
This product should not be thrown in the garbage.
In accordance with the European directive 2002/96/EC, electronic equipment at the end of their life must be collected and returned to an authorized recycling facility.
¥29.8
¥9.9
¥59.8